This account is already activated. Please login below. Your password has been changed. Register an account Please fill in all fields correctly. I accept the terms and conditions. I want to receive news and updates from Ontech. Select a new password Please fill in all fields correctly. The password could not be changed, this activation links is invalid. The password could not be changed, please try again. Request new password Please fill in all fields correctly. Please check your email for instructions.

There is no user with this email. In your house or cottage. Ontech Relay Please specify your problem in the form below and submit t to the support. This battery can also be used in places where there is no power jacket. Use an accumulator with voltage V. Page Push Button ordinary telephone. All alarm are acknowledged. The sign separates the command lines. See page Be sure you have programmed the SIM-card and not only the memory of the mobile phone. The identity of the unit In a system with one master unit and one or more slave units it is of utmost importance that all units has different ID numbers The master unit always has ID1.

During this operation the unit must be disconnected from all forms of power. A small screwdriver can be used. Put the power contact of the device you want to operate in the unit power socket. Page Operate The Relay With Sms After you done one operation you can directly execute next operation without hanging up the receiver. Page Alarm Function Alarm function The unit has two alarm inputs.

See page 20 Note that these inputs not can send an alarm again before the alarm has been acknowledge. Page 28 Acknowledge an alarm manually Press the button on the front of the unit at least once. Page Functions Functions Push button On the units front cover there is a push button.

One push on the button will switch the relay. The lamp of the unit On the front of the unit there is a red lamp. The relay is turned on Not lit The relay is turned off Flashing Check if the area is covered by using the SIM-card in a mobile phone..

Page Tip Tip! The sign separates all the command lines. Page 34 Page 35 The following happens: a. The green lamp starts flashing for about 45 seconds. This indicates that the unit is searching an GSM network. Finally the green lamp is lit. The unit is communicating with the GSM network and the unit is ready for use. If both the red and the green lamp is flashing, this indicates: i. SIM-kort is missing ii. See item 2. Insert the unit in the wall power socket you wish.

Put the power contact of the device you want to operate in the power socket of the unit. Operate the relay manually You can make the relay switch by pressing the button on the unit. When the relay is on, the red lamp is lit and when the relay is off, the red lamp is not lit. Operate the relay by calling it up 1. Call up the unit. Be sure you use tone mode on the telephone.

The unit answers with a beep. Press your PIN-code and then. Example: If the PIN-code is correct the unit replies with a beep. If it is not correct the call is disconnected. Call again and try. Hang up the receiver. If the unit replies with two beeps, try again. Turn on the relay with timer function The relay can be turned on and you can set the number of hours you want it to be active before it switches off between 1 and 99 h.

The unit replies with a beep. When you have executed all operation, hang up. Operate the relay with SMS 1. If you not are sure about the settings of the unit, you can request a status-SMS. See page Connect an alarm detector An alarm detector is a device that connects or disconnects a circuit when it is activated. Example of such devices are PIR units, magnetic detectors, level guards or similar.

On the bottom you will find a jacket with four connectors. They are numbered from Factory setting for switch no 1 is OFF. This means that the alarm inputs are set to NO mode. If switch no 1 is set to ON the NC mode is activated. See page 6. The reason for this is that you will have time to for example close a door that is alarmed.

If you want you can turn off the alarm function. Turn off the alarm function by calling up 1. Turn off the alarm function with SMS 1. If you not are sure about the settings of the unit you can send an SMS and ask for status. See page How you create this list, see page 6. The number indicates the unit, Ontech is always no 1, and the others refer to the slave units connected. Note that these inputs not can send an alarm again before the alarm has been acknowledged. Inputs: Indicates the alarm input that still is activated.

In this example 1b the SMS means that inputs 1a, 1b and 3b has been activated since the last acknowledge and that input 3b still is activated. Units: Indicates the units communicating with the master unit. The other numbers refers to the slave units connected. Alarmrelay on Indicates that the Temperature guard function is activated. Temp watch on Gives the temperature at the master unit in degrees Celsius. Temp Acknowledge an alarm When an alarm input is activated the unit will not be able to send a new alarm before the earlier alarm is acknowledged.

Note that also all alarm from the slave units will be acknowledged. Acknowledge an alarm by calling up 1. Acknowledge the alarm by pressing the buttons 9. Acknowledge an alarm with SMS 1. Temperature guard The unit can be set to automatic alarm when the temperature drops below 5 degrees Celsius.